SOLARCALCKIT SUITE / インバーター設計とDC電流

インバーター設計とDC電流

IEEE 929 & UL 1741 REFERENCE METHODOLOGY

合計連続ワット数とモーター起動サージに対応するインバーターを設計 — システム電圧でのDCバッテリー電流とヒューズ容量も確認できます。

AC Loads & Battery Path
Client-Side Engine
01 Connected AC Appliances
02 Battery Voltage & Efficiency

DC voltage the inverter draws from.

Conversion efficiency % (default 90%).

How inverter sizing works

An inverter converts DC battery power to AC for your loads. Sizing it is really two separate questions kept strictly apart: continuous power (what the inverter must supply indefinitely) and surge / peak power (the brief, higher draw when motors or compressors start).

Formulas

The inverter sizing math

Continuous watts, peak surge, and DC terminal current.

Continuous AC Watts

P_continuous = Σ load continuous watts

Steady-state power. Inverter continuous rating must exceed this value.

DC Battery Current

I_DC = P_AC ÷ (V_system × η)

Current drawn through DC battery cabling and main system fuse.

よくある質問

冷蔵庫とテレビに必要なインバーター容量は?

両者の連続ワット数を合計し、冷蔵庫の起動サージを確認します — コンプレッサーは1〜2秒間、定格の2〜3倍を消費することが一般的です。1000〜1500Wでサージ2000〜3000Wのインバーターなら、冷蔵庫+テレビを十分にカバーできます。

なぜサージ定格が重要なのですか?

モーター・ポンプ・コンプレッサーは起動時に定格を大きく上回る短時間のサージを必要とします。インバーターがそのサージを供給できないと、連続負荷が定格内でもシャットダウンやブレーカ動作が起こります。

インバーターはバッテリーからどれだけの電流を引きますか?

I_dc = P_ac ÷(V_システム × 効率)。12Vで90%效率のとき1000Wの負荷は約93Aを消費します — だからこそ、より高いシステム電圧と適切にヒューズ保護された短いDCケーブルが重要です。